Hurricane Sandy Sampling Results

On October 31, 2012, EPA took 4 samples in the Gowanus Canal area. Samples were taken from the ground floors of two buildings that had been flooded as well as directly from the canal. One of the buildings is located at the head of the canal, and the other near the 3rd street turning basin.
Samples of flood water from the ground floors of the two buildings were analyzed for bacteria and 139 different chemicals within the following categories: metals, volatile organic compounds, petroleum related compounds and semi-volatile organic compounds. Semi volatile organic compound include polycyclic aromatic hydrocarbons or PAHs, which are the primary contaminants in Gowanus Canal sediment.

Levels of bacteria were high. While this type of bacteria becomes inactive over time, these findings reinforce the need for people to protect themselves when cleaning up flood waters that contain sewage and therefore contain bacteria. Fact sheets detailing the precautions people should take when cleaning flood waters can be found at http://www.epa.gov/sandy/.

The remaining four categories of pollutants were compared to health based values of drinking water quality. Chemicals that were tested were below levels of concern or not detected.

Low levels of gasoline and diesel derivatives were found, consistent with road run-off which often contains traces of fuel.

Levels of semi-volatile organic compounds were very low or not detected. These compounds include PAHs, which are a primary contaminant in the sediments at the bottom of the canal. The presence of some PAHs at low levels may also be related to spilled fuel and run off from asphalt.

Levels of most volatile organic compounds and metals were very low or not at levels that could
be detected. Levels of metals included some slight exceedances of drinking water standards. In the case of lead, its presence may be related to past lead usage in gasoline, typical to an urban environment.

You can find the pdf here.

And the excel of the chart here: sandysampling (1).

About GYFO

Lover of all things Gowanus and Brooklyn!

Leave a Reply

Your email address will not be published. Required fields are marked *

* Copy This Password *

* Type Or Paste Password Here *

2,042 Spam Comments Blocked so far by Spam Free Wordpress

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>